AC current sensor connection (0-10V output)
AC current sensor can be used to monitor fan and pump status,
motors, compressors, and any other electrical equipment for proper operation.
A change in the operating current may indicate mechanical failure or that the
unit has been turned off. AC current sensors can be
used in load trending (current monitoring) type applications.
AC
current switch connection
AC current switch can be
used to monitor fan and pump status, motors, compressors, and any other electrical
equipment for proper operation. A change in the operating current may indicate
mechanical failure or that the unit has been turned off.
Water
and fuel Level Switch connection
Water, fuel and
other liquid level monitoring.
CO2
Sensoren
Soil
moisture sensor connection (4-20mA output)
The EA-10
Soil Moisture sensor (ECH2O EA-10 Dielectric Soil Moisture sensor) is designed
for use with industrial data acquisition and control systems. The EA-10 sensor
has a standard 2-wire, 4-20 mA analog interface. Supply voltage: line powered
7-32 Volt; DC Overvoltage and reverse polarity protected
Liquid
Flow Switches, Gas Flow Switches
Optic
Leak Detection Switch LO10
(the general purpose optic switch is a great choice for leak detection in and
around secondary containment sumps, tanks and pipes. The sensor can be applied
in a broad range of chemical solutions. Media), Thermal Dispersion Flow Switch
FT10 (the
general purpose liquid flow switch) and Thermal Dispersion Flow Switch
GT10 (the general purpose gas flow switch). Adjustable set point. NO / NC
Output. The product is broadly selected for low or no-flow applications.
Contactor
connection
A contactor is an electro-magnetic switching
device (a relay) used for remotely switching a power or control circuit. A contactor
is activated by a control input which is a lower voltage / current than that which
the contactor is switching.
Soft
Starter connection
A motor soft starter is a device
used with AC electric motors to temporarily reduce the load and torque in the
powertrain of the motor during startup. This reduces the mechanical stress on
the motor and shaft, as well as the electrodynamic stresses on the attached power
cables and electrical distribution network, extending the lifespan of the system.
Temperature
sensor Smartec SMT160-30 connection
The
SMT160-30 (TO18 model) has an overall accuracy of 0.7 °C in the range from -30
°C to +100 °C and an accuracy of 1.2 °C from -45 to +130 °C.
SMT1603018
Probe: stainless steel tube 7 mm. x 40 mm. Cable: 5 m. PVC shielded, 3.5 mm. Absolute
accuracy .7 °C Linear output within .2 °C.
Battery
via magnetic contact connection
(BR160SM-V for vending machine or other applications;
consumption from battery)