Current sensors | Liquid Level Sensors | Flow and Pressure Sensors
Moisture / Humidity Sensors | Temperature Sensors | CO2 and PH Sensors
Output Control | Power Supply and Battery powered
Energy parameter
monitoring.
AC Current Sensor. AC Current Switch. Ground Fault Sensor,
DC
Current Switch and DC Current Transducer.
DC Hall Effect Current Transducers
and
True RMS AC Current Transducer
AC current sensor connection
AC current switch can be used to monitor fan and pump status, motors, compressors,
and any other electrical equipment for proper operation. A change in the operating
current may indicate mechanical failure or that the unit has been turned off.
AC current sensors can be used in load trending (current monitoring)
type applications.
AC
Current sensors (split or solid core). The
CTA
and CTV
Series current sensors monitor the current flowing to electrical equipment or
buildings. The magnitude of this current is then converted into a linear 4...20
mA or 0...10Vdc output signal. All of these sensors have jumper selectable input
ranges 0-10, 0-20, 0-50A for CTV-50
or SCTV-50 (or 0-100, 0-200, 0-250A for CTV-250
or SCTV-250). These current sensors should be used in load trending (current
monitoring) type applications. The current sensors are fast acting, reliable,
and extremely easy to install. No additional din rail mounting clips are necessary,
due to the unique design of the integral din rail mounting flange.
The CS
series current sensors monitor the current flowing to electrical equipment or
buildings. The magnitude of this current is then converted into a linear 4-20mA
or 0 to 10 VDC output signal, which can be monitored by a Building Management
System. The units have jumper selectable input ranges. These current sensors should
be used in load trending (current monitoring) type applications. CS-SD10L
or CS-SP10L - range 0...10/20/50A or for CS-SD10
or CS-SP10 0...100/150/200A.
AC current switch connection
AC current switch can be used to monitor fan and pump status, motors, compressors, and any other electrical equipment for proper operation. A change in the operating current may indicate mechanical failure or that the unit has been turned off.
AC
Current switch (split or solid core). AC
current switches should be used in applications in which a “Go/No Go” current
switch is required. A current switch can be used to monitor fan and pump status,
motors, compressors, and any other electrical equipment for proper operation.
A change in the operating current may indicate mechanical failure or that the
unit has been turned off.
The CSW
series of AC current switches activate a normally open (NO) contact closure via
a solid-state switch whenever the monitored primary circuit current exceeds a
pre-set level. Models are available to switch various load types. The CSW series
current switches can be used to monitor devices with a maximum continuous operating
current of up to 200 Amps and the power supply is induced from the conductor being
monitored. Fixed or adjustable setpoint
The CS-F
series current switches are available in a solid-core or split-core with Normally-Open
(N/O) output configurations. All of these sensors will have a solid-state output
with a fixed trip point (setpoint). These current switches are ideal for providing
status information on any type of AC current using equipment.
Ground
Fault Sensor, DC Current Switch and
DC Current Transducer connection
Ground
Fault sensor - Normally Energized: protection from fault or loss of control power.
Normally Deenergyzed: protection from faults only when control power is applied.
Current Operated Switches. Input.
With Relay output (SPDT) or Solid State
Output (Normally Open). DC Current Transducer for
DC measurement.
AKS-C
NOAC Ground Fault Sensor, Factory adjusted
set point. NO output. Primary current 5 - 950 mA AC. Normally Energized: protection
from fault or loss of control power. Normally Deenergyzed: protection from faults
only when control power is applied. DKS
100 C Current Operated Switches. Input - 4-20A, 10-50A, 15-100A (with
manual jumper). Hysteresis is 5% of set point. DFS 100C SDT - Relay output (SPDT)
or DKS 100C NOW - Solid State Output (Normally Oupen). DC Current Transducer.
Split or solid core. 0-5VDC output DK-B5
0-10VDC output DK-B10
proportional to measured current. For DC measurement. Jumper selectable range.
DC
Hall Effect Current Transducers
True RMS AC Current Transducer
True RMS AC Current Transducer
The
CR5200
Series, DC Hall Effect Current Transducers are designed to output a DC signal
which is proportional to a DC current input signal. These devices are designed
for direct current only, targeting them towards general and daily applications.
0-5Vdc or 4-20mA DC outputs. Supply Voltage: 24 VDC. The CR4100
Series True RMS Current Transducers and Transmitters are designed for applications
where AC current waveforms are not purely sinusoidal. More precise and accurate
than other transducers, these devices are ideal in chopped wave and phase fired
control systems. 0-5Vdc or 4-20mA DC outputs.
Current sencor compatibel with BR16GM-2A/-4A, BR160GM-2A/-4A, BR160SM-2A/-4A,
BR128GM-4A/-Pt1000, BR1280GM Current switch compatibel with all
our modules BR16GM, BR160GM, BR160SM, BR128GM, BR1280GM