with
build-in GSM modem Telit GM862
|
GSM modules for Pt1000 (Pt100) temperature
sensors support. GPRS/FTP Data Logger.
BieneRemote1281GM-4Pt1000/4A,
- module with 4 Pt1000 (Pt100 optional) temperature inputs (with Smartec
Universal Transducer-Interface UTI). For 4 Pt1000 (Pt100) temperature sensors
connection. Also 4 analog inputs, 6 digital inputs and 5 outputs. Designed to
be used for remote control, monitoring and alarming via GSM (for temperature monitoring,
analog and digital signal monitoring). Data Logger function -analog and digital
data - file transfer to FTP server via GPRS. Board size: 165 x 145
mm. BieneRemote1281GM-4Pt1000/4A - with or without Power
Supply on board. Modules support internal control and module
module communication. Internal control - Output control from input events. Module-Module
communication via SMS- output control from input events on remoted modules. |
| BR1281GM-4Pt1000/4A |
Communication |
via GSM GSM 850/900/1800/1900 |
Command
and data transmission | SMS/GPRS/FTP |
Internal GSM modem |
Telit GM862-QUAD |
SIM
card reader | Yes |
SIM card type | phase
2 GSM11.14 - SIM 3V |
Firmware |
Yes |
Digital
inputs | |
Number of digital inputs | 6 |
- Transistor digital input | 6
("0": 0...+1V; "1": +1.5
+12V without external limited resistor) |
- Events digital inputs |
6 |
- Digital signal filter
| 25ms - 9 sec |
Temperature sensor inputs | |
Number of temperature inputs |
4 |
Temperature events
inputs | 4 |
Temperature sensor type |
Temperature sensor Pt1000 (Pt100 optional) |
Temperature range |
-99 to +149 °C or -146 to 300°F |
Events Temperature range |
-99 to +149 °C or -146 to +300 °F |
Accuracy | 0.2°C
or 0.4°F |
Analog inputs |
|
Number
of analog inputs | 4 |
0...+5V / 0...+10V,
0-20mA/4-20mA 100kom typ |
- Analog event inputs | 4 |
ADC resolution | 10
bit |
Outputs | |
Number of outputs | 5 |
- MOSFET transistor outputs | 4
(MOSFET SST5NF20V, 20V max) |
-
Relay outputs | 1
(NO, NC, COM; 24VDC/1A max 120VAC/0.5A max) |
- impuls output | 1 (output 4) |
Data Logger (optional) | |
- Time interval | 30
sec ... 300 sec |
- Logged parameter |
temperature, analog data, digital input and output, status |
- Output source |
RS232 and FTP |
Power Supply |
|
Required Power supply |
External +12 VDC stabilized as optional |
Power requirement | 800mA(rms)
max, 2A peak during transmission |
Voltage
regulator | Internal voltage
regulator |
Power protection |
Reverse-polarity protection |
Environmental
Conditions | |
Normal operational temperature range |
-10
+55°C |
Extreme operational
temperature range (these temperature can affect the sensitivity and performance
of the module) | -20
+70°C |
Phisical parameter | |
Board dimension | 100x62mm |
| BR1281GM-4Pt1000/4A |
Number of controlled outputs | 5 |
Number of digital event inputs | |
Number of readable digital inputs | |
Number of temperature event inputs | 4 |
Number of analog event inputs | 4 |
Number of readable analog data | 4 |
Authorization cell phone numbers | 7 |
Events cell phone numbers | 4
(external cell phone) +3 (external BieneRemote module) |
SMS
events format | Text message |
SMS digital data format | Binary |
SMS message format for analog data | In
% from Reference level 00 - 99 |
Metric system
temperature | °C
or °F |
SMS message format for temperature
data | min level 2,
min level 1, max level 1, max level 2 measurement -99°C - +149°C
-146 to 300°F events level -99°C - +149°C -146°F
- +300°F |
|
SMS
in EEPROM | Temperature
Events | 1 | T1
< min level 2 | 2 | T1
< min level 1 | 3 | T1
normal | 4 | T1
> max level 1 | 5 | T1
> max level 2 | 6 | T2
< min level 2 | 7 | T2
< min level 1 | 8 | T2
normal | 9 | T2
> max level 1 | 10 | T2
> max level 2 | 11 | T3
< min level 2 | 12 | T3
< min level 1 | 13 | T3
normal | 14 | T3
> max level 1 | 15 | T3
> max level 2 | 16 | T4
< min level 2 | 17 | T4
< min level 1 | 18 | T4
normal | 19 | T4
> max level 1 | 20 | T4
> max level 2 | | |
SMS
in EEPROM | Analog
Events | 21 | A1
< min level 2 | 22 | A1
< min level 1 | 23 | A1
normal | 24 | A1
> max level 1 | 25 | A1
> max level 2 | 26 | A2
< min level 2 | 27 | A2
< min level 1 | 28 | A2
normal | 29 | A2
> max level 1 | 30 | A2
> max level 2 | 31 | A3
< min level 2 | 32 | A3
< min level 1 | 33 | A3
normal | 34 | A3
> max level 1 | 35 | A3
> max level 2 | 36 | A4
< min level 2 | 37 | A4
< min level 1 | 38 | A4
normal | 39 | A4
> max level 1 | 40 | A4
> max level 2 | | |
SMS
in EEPROM | Digital
Events |
41 | Input 1 0-1 |
42 | Input 2 0-1 |
43 | Input
3 0-1 | 44 | Input
4 0-1 | 45 | Input
5 0-1 | 46 | Input
6 0-1 | 47 | Input
7 0-1 | 48 | Input
1 1-0 | 49 | Input
2 1-0 | 50 | Input
3 1-0 | 51 | Input
4 1-0 | 52 | Input
5 1-0 | 53 | Input
6 1-0 | 54 | Input
7 1-0 | | Nr
| admin
cell phone number in SIM Phone Book |
1 | Number 1 |
2 | Number
2 | 3 | Number
3 | 4 | Number
4 | 5 | Number
5 (external BR) | 6 | Number
6 (external BR) | 7 | Number
7 (external BR) |
|